Step Table
An eight-slot lookup table for CV. You dial a value into each of eight steps, then feed an index voltage to read them back — a simple, direct way to turn a counter, ramp, or LFO into a sequence of fixed voltages.
How it works
The index input spans 0 to 10V across the eight slots, so an incoming voltage picks one step and the out jack passes that step's stored value. Drive the index from a clocked counter and the table plays as a sequencer; sweep it with an LFO and you scan the values smoothly in steps.
Controls
- Step 1–8 — the value held in each slot, from
0to10. Whatever step the index lands on appears at the output.
Inputs & outputs
- Index — selects the active slot;
0–10Vmaps across the eight steps. - Out — the value stored in the selected step.
Tips
- Patch a stepped or clock-divided ramp into Index to step through the table as a melody or modulation sequence.
- Send the output through a quantizer to lock the eight values to a scale.